TOPKAPI Scada Available protocols

for the 32 bits version of TOPKAPI Vision

acquisition

Any protocol using a serial port will be available for serial devices which are Windows compatible, such as multiport boards RS232C, RS422, RS485 or serial to Ethernet products.

Acquisition by OPC SERVER

If the "SUPPORT" column  indicates "OPC Server", you must acquire an appropriate OPC Server, not supplied with TOPKAPI.

OPC SERVER

TOPKAPI can be used as an OPC Server for each of the protocols listed hereafter. Regarding protocols for which "OPC Server" is mentioned in the "SUPPORT" column, this generally has no interest (except in special cases) as we otherwise have an OPC Server.

For protocols with time-stamped data, TOPKAPI provides built-in modem management and historical data storage in any SQL compliant DBMS (Oracle, SQL Server, MySQL, PostgreSQL, etc.).

GATEWAY FUNCTION

TOPKAPI can be used as Gateway between several systems using distinct protocols.


Information below is applicable for the supply of the current TOPKAPI version. A version update may be required when adding a new protocol driver to an old TOPKAPI version, for technical or support reasons : please contact us.

Languages:

Engl for English, Sp for Spanish, Fr for French.

In Spanish, if this language is not available, the English driver is installed, but it is also possible to install manually the French version of the driver.

Depending on requirements, protocols can be translated : please contact us.

N.B. : All the protocols with real-time and time-stamped data, without intermediary front end with a modem management, need a modem management library.

PROTOCOLS

SUPPORT
Time- Stamped

Support

(1)

Language
OBSERVATIONS

ABB Aquamaster

SMS via GSM Modem

Engl/Sp/Fr 

ACT'L

  See EWON

ADCON

OPC ServerEngl/Fr

OPC Server provided by ADCON

ALLEN BRADLEY

All protocolsOPC Server Engl/FrContact Allen Bradley or OPC server providers.
DF1, DH485, DH, DH+, console plugOPC Server or

WOODHEAD-APPLICOM card(4)

 

Engl/Sp/Fr

Please contact WOODHEAD-APPLICOM.

KF2 adapter required for DH+

Modbus, Modbus TCPTOPKAPI direct driver Engl/FrMany providers of PLC communication cards (Allen Bradley, Prosoft) or gateways.

AMPHITEC

Serial port

 

Fr

 

AQUACOM

Serial port or modem

Fr/Eng

See XYLEM

ARITECH - MPI 232 (3)

Serial port

 

Fr

CD 150 Units

ASI (AS-i)

Specialized cards (4)

 

Fr/Eng

OPC Server requested, to be provided with the board

OPC Server or Gateway 

Engl/Fr

Gateway AS-I to Modbus, Modbus Plus, Profibus DP, Interbus, DeviceNet, CANopen, CANrho (Bosch), CC-Link, LON, Modbus, TCP

BACNET

TOPKAPI direct driverEngl/FrEthernet port, serial connection via router.

BAELZ

Serial port or ModemEngl/FrJbus + specific layer fort time-stamp processing

BATIBUS

WOODHEAD-APPLICOM card (5)

 

Engl/Sp/Fr

 

BERIS (DATAM)

Serial port

 Fr 

BOBITECNIC

Standard port + ModemFr/Sp 

BOSCH D6600

Serial portFrFront End Equipment D6600

CAIRPOL - Micro-sensor CairSens

GPRS via FTP ServerFr

Miniature air quality monitoring system

CD 150 ARITECH

   

See ARITECH

CESA (3)

FrontalFrFrontal PE1200 - Please contact us

CR2M ALNAEE

Standard port + Modem

Fr

 

CR2M SAB600 / SAB6000

Standard port + Modem

Fr

 

DATALOGGER IT

File ProtocolFrPlease contact us

DATAM FLUTEC
TM 16000  XC
(F4 Front End)

Serial port + F4 Front EndFr 

DATBUS2 (DATAM - FLUTEC / ARCANTE / APILOG)

Standard port + Modem

Fr

 

DDE

Soft

 

Engl/Fr

All servers (2)

DEF (NOVA, ALTARES, ANTARES)

Serial port or Ethernet TCP/IP port

 

Engl/Sp/Fr

Fire Detection System Units (FDSU) & Fire Safety Controller Units (FSCU). Preset objects FD & SAD, import, AUTOCAD links: Please contact us for more details.

DNP 3.0

Native TOPKAPI Driver

Engl/Fr

 

ENDETEC KAPTA 3000 sensor

GPRS via FTP Server

Engl/Fr

 

ETHWAY, FIPWAY, MAPWAY

Specialized cards (4)

 Engl/Sp/Fr

Windows 98/NT/2000/XP Pro

Library YCCFPWPCV1 (Fipway) or YCCETHPCV1 (Ethway) required

WOODHEAD-APPLICOM card (5)

 Engl/Sp/Fr

Ethway, Fipway

Specialized cards (4) Engl/Sp/Fr

Only with Win 95/98, not WinNT: possible connection with the SCHNEIDER basic drivers, delivered with the Fipway/Ethway card, using the TOPKAPI 16 bits driver working in the compatibility mode.

ETIC

Standard port + Modem

Fr

 

EWON

TCP/IP or Standard port modem

Engl/Fr

 

EXEMYS

Standard port + Modem

Engl/Fr

 

GE - FANUC and CEGELEC SNP-X

WOODHEAD-APPLICOM card (5) Engl/Sp/Fr 

GE - FANUC Series 90-30 and 90-70 SRTP

WOODHEAD-APPLICOM card (5) Engl/Sp/Fr 

GERRIS - SAPPEL

  See WAGAMET Ortomat

HWM (RADCOM)

MultilogStandard port + Modem (PSTN) / SMS via GSM Modem / GPRS via FTP Server / GPRS via HWM ‘Toran’ driver*Engl/Sp/Fr

(6)

*Subject to the compatibility with Toran - Consult HWM

PegasusPlus
MultilogLXSMS via GSM Modem / GPRS via FTP Server / GPRS via HWM ‘Toran’ driver*Engl/Sp/Fr

(6)

*Subject to the compatibility with Toran - Consult HWM

PermanetPlus

HYDREKA

Eurolog (3)Standard port + Modem  
HydrinsSMS via GSM Modem + GPRS via FTP ServerEngl/FRInsertion Flow meter
Multilog / Octopus LXSMS via GSM Modem + GPRS via FTP ServerEngl/Sp/Fr(6)
OctopusStandard port + Modem  
OdalogGPRS via FTP Server  
Permalog+ / AMRGPRS via FTP ServerFr

Leak pre locator. Acquisition via Radio-Tech Hub.

IDEC IZUMI

Serial port

 

Engl

 

IDS ARCOS 750,
IDS 650/850

   

See IEC 60870-5-101

and IEC 60870-5-104

IEC 60870-5-101

Serial port

Engl/Fr

 
Serial port + Modem

Engl/Fr

Modem link is not supported by all devices which are IEC 60870-5-101 compliant.

Please contact us to confirm compliance of the selected device with TOPKAPI.

IEC 60870-5-102
IEC 60870-5-103

Serial, modem, radio

 

Engl/Fr

OPC server developed by third party companies: please contact us.

IEC 60870-5-104

TCP-IP

Engl/Fr

GPRS compliant.

IJINUS

SMS via GSM Modem + GPRS via FTP ServerEngl/Sp/Fr(6)

INT2500 AGBAR

Serial port + modem

Engl/Sp/Fr

Modbus serial or modem, time stamped at the source (Areal format)

INTELLISONDE

GPRS via FTP ServerFrMulti parameters sensors  for water quality management. See INTELLITECT WATER.

ISCO 2150 (TELEDYNE)

Serial port + modem

Fr

 

ITT FLYGT

   See XYLEM

JBUS

   See MODBUS

JEL (3)

Serial port

   

JOHNSON CONTROL

IM9100Standard port + Modem

Fr

 
OPTOMUX   See OPTOMUX

KNX

OPC Server Engl/Fr

NETx AUTOMATION's NETx KNX OPC Server successfully tested.

Others: please contact us

KOSKAS Geoloc

SMS via GSM ModemEngl/Sp/Fr(6)

LAC

DDE server

 

  

LANDIS and STAEFA (RH 500, NITEL)

Serial port

Fr 

LON.LONWORKS

OPC Server

 

Engl/Fr

GESYTEC's EASYLON OPC Server successfully tested.

Others: please contact us

MIRI (OVAL) AD2000

Serial port + ModemEngl/Fr

Contacts :
Oval / Miri

OPC Server

 

Engl/Fr

MITSUBISHI FX

OPC Server

 

Engl/Fr

OPC Server Melsec FX

MODBUS JBUS Master

Serial port

Engl/Sp/Fr

Time stamp processing : SEPAM 2000 format, or AREAL's advanced formats. please contact us

Standard port + Modem

Engl/Sp/Fr

MODBUS JBUS Slave

Serial port

 

Engl/Fr

Can also be used for routing and / or communication gateway

MODBUS TCP-IP Master

TCP-IP

Engl/Sp/Fr

Time stamp processing : SEPAM 2000 format, or AREAL's advanced formats. please contact us

MODBUS TCP-IP Slave

TCP-IP

 

Engl/Fr

Can also be used for routing and / or communication gateway

MODBUS PLUS

Specialized cards(4)

 

Fr/Sp

 

MPI 232

   

See ARITECH

NAPAC - NAPBUS

Standard port + Modem

Fr

TBC type units.
Standard port + Modem or TCP-IP Network

Fr

XFLOW type units: Flowtel, Phoenix, Rio, etc.

NUGELEC

Serial port

 

Fr

 

OMRON

SYSMACWAY / Serial port

 

Fr

 

OPC Omron server

 

Engl/Fr

Please, contact OMRON for supported devices

OPC

Depending on the server supplier

 

Engl/Fr

Please, consult us if needed

OPTOMUX

Serial port

 

Fr

 

OTIC FISHER DATALINK

WOODHEAD-APPLICOM card(5)

 

Engl/Sp/Fr

 

OTT

DuoSensSMS via GSM ModemEngl/Sp/FrDatalogger (6)
LogoSensSMS via GSM ModemEngl/Sp/FrDatalogger (6)

PACSNET (3)

PACS Radio modemFr 

PALMER Permanet

SMS via GSM ModemEngl/Sp/Fr(6)

PARATRONIC

GPRS via FTP ServerFrLNS equipment - xml file supported

PERAX

Standard port + Modem or Arlequin Front EndEngl/Sp/FrP200, P200x, P400xi, P16XT

PERAX SMS (P16XT)

SMS via GSM ModemEngl/Sp/Fr

(6)

PERAX SMARTLOG

SMS via GSM Modem + GPRS via FTP ServerEngl/Fr

Included in the up-to-date PERAX protocol (version 5.1). GPRS connection can be backed up by the SMS connection

PRIMAYER

PhocusSMS via GSM ModemEngl/Sp/Fr(6)
PrimelogSerial port + ModemEngl/Sp/Fr 
XilogSMS via GSM ModemEngl/Sp/Fr(6)
Xilog+SMS via GSM Modem + GPRS via FTP ServerEngl/Sp/Fr(6)

PROFIBUS / SINEC L2

WOODHEAD-APPLICOM card (5)

 

Engl/Sp/Fr

 
OPC Server Engl/Fr

OPC Server SCOUT.

Please contact SIEMENS for protocols handled and hardware required.

ROCKWELL

   See ALLEN BRADLEY

SAC (3)

Serial port

   

SAE-IT

 

 See IEC 60870

SATCHWELL

DDE MICRONET Server

Fr

Local or remote via modem, no time stamped data.

SAUTER

BACNETEthernet IP Engl/Fr 
NOVANET (EY3600, MODULO2)

Serial port

FrSerial (local)/modem (remote) link to Router/Routel unit for fieldbus NOVANET
Others   See BACNET or LON

SBUS - SAIA

WOODHEAD-APPLICOM card(5)

 

Engl/Sp/Fr

 

SCHNEIDER ELECTRIC

JBUS - MODBUS   See MODBUS
MODBUS IP   See MODBUS TCP-IP

SCHNEIDER ELECTRIC
NAPBUS, XFLOW

   See NAPAC

SHNEIDER ELECTRIC SCADAPack

Serial port or TCP-IP : DNP3 protocol

Engl/FrSee DNP3 protocol - Auto-configuration with Unity (for recent versions of SCADAPack)

SCHNEIDER ELECTRIC W@DE

Standard Port + Modem

Engl/FrW@DE W320, W330, ...

SCHNEIDER ELECTRIC (TELEMECANIQUE)
ETHWAY, FIPWAY, MAPWAY

Specialized cards (4)

 

Engl/Sp/Fr

Windows 98/NT/2000/XP Pro

Library YCCFPWPCV1 (Fipway) or YCCETHPCV1 (Ethway) required

WOODHEAD-APPLICOM card (5)

 

Engl/Sp/Fr

Ethway, Fipway

Specialized cards (3) (4)

 

Engl/Sp/Fr

Only with Win 95/98, except WinNT: possible connection with the SCHNEIDER ELECTRIC basic drivers, delivered with the Fipway/Ethway card, using the TOPKAPI 16 bits driver working in the compatibility mode.

OPC Server Engl/Fr

Server OFS of SCHNEIDER ELECTRIC. To consult SCHNEIDER ELECTRIC according to your network and your equipment

SCHNEIDER ELECTRIC
TCP/IP (See Modbus-Jbus Master in TCP-IP too)

Specialized cards (4)

 

Engl/Sp/Fr

IPC UNI-TE library required
WOODHEAD-APPLICOM card (5) 

Engl/Sp/Fr

 

SCHNEIDER ELECTRIC
ISAWAY

Specialized cards (4)

 

Engl/Sp/Fr

UNI-TE/ISAWAY PCUNI-TE library needed

SCHNEIDER ELECTRIC
UNITELWAY Slave

Serial port

 

Engl/Sp/Fr

The driver can be used in slave mode only.

SCHNEIDER ELECTRIC
UNITELWAY Master or Slave

WOODHEAD-APPLICOM card (5) 

Engl/Sp/Fr

 

SCHNEIDER ELECTRIC UNITY-PRO

  Engl/FrAccording to the protocol in use (see above), most frequently SCHNEIDER ELECTRIC's OFS server (OPC).

SDG (Lyonnaise des Eaux)

TCP/IP Network card

Engl/Fr

 

SEBA Hydrometrie

Standard port + Modem

Sp/FrMDS5 devices

SEBA KMT

FTP / GPRS

 Please contact us

SECURITE COMMUNICATION (PE1200) (3)

Front end

Fr

 

SERIEE

EROS20 Front end PC

Fr

 

SEVME (Sevbus)

Standard port + ModemEngl/Sp/Fr 

SEWERIN Sepem

SMS via GSM ModemEngl/Sp/FrLeak prelocator.(6)
3964RWOODHEAD-APPLICOM card (5) 

Engl/Sp/Fr

 

Serial port by the WOODHEAD-APPLICOM server SPWIN

 Engl/Fr (3)
AS511(S5)WOODHEAD-APPLICOM card (5) 

Engl/Sp/Fr

 
Building Technologies CERBERUSSerial port or Ethernet TCP/IP port Engl/Sp/Fr

Via Modbus gateway provided by Siemens-Cerberus.

Fire Detection System Units (FDSU) & Fire Safety Controller Units (FSCU). Preset objects FD & SAD, import, AUTOCAD links: please contact us for more details.

Building Technologies LANDIS and STAEFA (RH500, NIDES, NITEL)Serial port + modemFrNRK16, NRK9, NRV (A, B, C, D), NRD.

Details

INDUSTRIAL ETHERNETOPC Server SCOUT 

Engl/Fr

Please contact SIEMENS

OPC Server WOODHEAD-APPLICOM (5) Engl/Fr

WOODHEAD-APPLICOM card not required (use of standard network adapter)

Please contact WOODHEAD-APPLICOM

SINEC H1WOODHEAD-APPLICOM card (5) 

Engl/Sp/Fr

 
SINEC L1DDE Server (2) or

WOODHEAD-APPLICOM card (5)

 Engl/Fr 
PROFIBUS / SINEC L2WOODHEAD-APPLICOM card (5) Engl/Sp/Fr 
OPC Server Engl/Fr

OPC Server SCOUT

Please contact SIEMENS for protocols handled and hardware required.

SNMP Manager

Ethernet /
TCP-IP

 Engl/FrUsed for data acquisition

SNMP Agent

Ethernet /
TCP-IP

 Engl/FrUsed to make data available to SNMP manager.

Can be used as protocol gateway.

SNP -X (GE - Fanuc and CEGELEC)

WOODHEAD-APPLICOM card (5)

 

Engl/Sp/Fr

 

SOFREL LACBUS
(S500/S550, LS10, LS42)

Standard port + ModemEngl/Sp/Fr

Support of event-driven communication

TCP-IP / GPRSEngl/Sp/Fr

Support of event-driven communication

FR1000 Front End

Engl/Sp/Fr 

SOFREL SOFBUS
(S10, S15, S40, S500/S550, LS10, LS42)

Standard port + ModemEngl/Sp/Fr

Support of event-driven communication

TCP-IP / GPRSEngl/Sp/Fr

Support of event-driven communication

 CS100 / FR1000 Front End

Engl/Sp/Fr 

SOFREL SMS (CELLBOX, LS10, LS42)

SMS via GSM ModemEngl/Sp/Fr

(6)

SRTP (GE - Fanuc Serie 90-30 and 90-70)

WOODHEAD-APPLICOM card (5)

 

Engl/Sp/Fr

 

STRATEL

Serial port + Modem FrPlease contact us for hardware required.

SUCOMA (KLÖCKNER-MOELLER) (3)

Serial port

   

WOODHEAD-APPLICOM card (5)

 

Engl/Sp/Fr

 

SULZER (SICOS)

Serial port

  via Front end: please contact us.

SYSMACWAY (OMRON)

Serial port

 

Fr

 

WOODHEAD-APPLICOM card (5)

 

Engl/Sp/Fr

 

TBOX (Semaphore - Technotrade)

Standard port + Modem

Engl/Sp/Fr

 

TECHNOLOG

CELLO

 SMS via GSM Modem

Engl/Sp/Fr(6)
Newlog

Standard port + Modem

Fr

 

TEXAS INSTRUMENTS TI-DIR (TI505)

WOODHEAD-APPLICOM card (5)

 

Engl/Sp/Fr

 

TRS II (WIT, TRSII, AQUAVEIL)

Standard port + Modem

Engl/Sp/Fr

 

MONET/Aquaveil II Front end

Engl/Sp/Fr

 

UNITELWAY Master or Slave

   See SCHNEIDER ELECTRIC above

VIZIMAX (RightWON)

Serial or Ethernet port

 See IEC 60870, DNP3

Serial or Ethernet port

  See MODBUS

WAGAMET Ortomat

SMS via GSM ModemEngl/Sp/Fr(6)

WEBDYN

GPRS via FTP server

Fr

WebdynTIC gateway use to collect electrical counting data.

XYLEM

MACTEC (Aquacom)Port série + Modem

Engl/Fr

Self configuration by SOFTLINK wizard using the .ATF files

Station SRX 104 (Aquacom) (3)

Port série

   

Many OPC Servers or DDE servers are also available, and AREAL develops protocols according to your requirements.

 

Version:
32 means that the protocol is fully compatible.
16 means that a thunk layer has been developed ; the protocol 16 bits works with Windows 95/98 and Windows NT. Port numbers available for 16 bits drivers are 1 to 10 (Windows 9x) and 1 to 9 (Windows NT).

 

(1) The mark means that the processing of the source timestamp is built-in.

(2) Contact us for validation of the server according to the supplier.

(3) Special Conditions : contact us.

(4) When changing the computer, make sure the specialized card is suitable for the new computer (PC bus ISA >>> PCI in particular) and the new operating system. For instance when using FIPWAY, only WOODHEAD-APPLICOM cards were available early 2006 for PCI bus. In doubt, contact AREAL.

(5) WOODHEAD-APPLICOM cards: www.applicom-int.com. When changing the computer, make sure the card is suitable for the new computer (bus and operating system).

(6) SMS protocol driver, version 3.6 and later. Requires a GSM subscription (voice only, data mode not required), no outgoing calls. The line and modem can be shared with the remote alarm notification module (Visiterm), or with other SMS protocol drivers. Check SMS MODEMS sheet for recommended equipment.